Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Sci Data ; 11(1): 483, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38729970

RESUMO

The Sparsely Annotated Region and Organ Segmentation (SAROS) dataset was created using data from The Cancer Imaging Archive (TCIA) to provide a large open-access CT dataset with high-quality annotations of body landmarks. In-house segmentation models were employed to generate annotation proposals on randomly selected cases from TCIA. The dataset includes 13 semantic body region labels (abdominal/thoracic cavity, bones, brain, breast implant, mediastinum, muscle, parotid/submandibular/thyroid glands, pericardium, spinal cord, subcutaneous tissue) and six body part labels (left/right arm/leg, head, torso). Case selection was based on the DICOM series description, gender, and imaging protocol, resulting in 882 patients (438 female) for a total of 900 CTs. Manual review and correction of proposals were conducted in a continuous quality control cycle. Only every fifth axial slice was annotated, yielding 20150 annotated slices from 28 data collections. For the reproducibility on downstream tasks, five cross-validation folds and a test set were pre-defined. The SAROS dataset serves as an open-access resource for training and evaluating novel segmentation models, covering various scanner vendors and diseases.


Assuntos
Tomografia Computadorizada por Raios X , Imagem Corporal Total , Feminino , Humanos , Masculino , Processamento de Imagem Assistida por Computador
2.
IEEE J Biomed Health Inform ; 28(1): 100-109, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37624724

RESUMO

Recently, deep learning has been demonstrated to be feasible in eliminating the use of gadoliniumbased contrast agents (GBCAs) through synthesizing gadolinium-free contrast-enhanced MRI (GFCE-MRI) from contrast-free MRI sequences, providing the community with an alternative to get rid of GBCAs-associated safety issues in patients. Nevertheless, generalizability assessment of the GFCE-MRI model has been largely challenged by the high inter-institutional heterogeneity of MRI data, on top of the scarcity of multi-institutional data itself. Although various data normalization methods have been adopted to address the heterogeneity issue, it has been limited to single-institutional investigation and there is no standard normalization approach presently. In this study, we aimed at investigating generalizability of GFCE-MRI model using data from seven institutions by manipulating heterogeneity of MRI data under five popular normalization approaches. Three state-of-the-art neural networks were applied to map from T1-weighted and T2-weighted MRI to contrast-enhanced MRI (CE-MRI) for GFCE-MRI synthesis in patients with nasopharyngeal carcinoma. MRI data from three institutions were used separately to generate three uni-institution models and jointly for a tri-institution model. The five normalization methods were applied to normalize the data of each model. MRI data from the remaining four institutions served as external cohorts for model generalizability assessment. Quality of GFCE-MRI was quantitatively evaluated against ground-truth CE-MRI using mean absolute error (MAE) and peak signal-to-noise ratio(PSNR). Results showed that performance of all uni-institution models remarkably dropped on the external cohorts. By contrast, model trained using multi-institutional data with Z-Score normalization yielded the best model generalizability improvement.


Assuntos
Gadolínio , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Redes Neurais de Computação , Razão Sinal-Ruído
3.
Sci Rep ; 13(1): 21231, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-38040865

RESUMO

Cerebral organoids recapitulate the structure and function of the developing human brain in vitro, offering a large potential for personalized therapeutic strategies. The enormous growth of this research area over the past decade with its capability for clinical translation makes a non-invasive, automated analysis pipeline of organoids highly desirable. This work presents a novel non-invasive approach to monitor and analyze cerebral organoids over time using high-field magnetic resonance imaging and state-of-the-art tools for automated image analysis. Three specific objectives are addressed, (I) organoid segmentation to investigate organoid development over time, (II) global cysticity classification and (III) local cyst segmentation for organoid quality assessment. We show that organoid growth can be monitored reliably over time and cystic and non-cystic organoids can be separated with high accuracy, with on par or better performance compared to state-of-the-art tools applied to brightfield imaging. Local cyst segmentation is feasible but could be further improved in the future. Overall, these results highlight the potential of the pipeline for clinical application to larger-scale comparative organoid analysis.


Assuntos
Cistos , Organoides , Humanos , Organoides/patologia , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Cistos/patologia , Inteligência Artificial
4.
Sci Data ; 10(1): 796, 2023 11 11.
Artigo em Inglês | MEDLINE | ID: mdl-37951957

RESUMO

The availability of computational hardware and developments in (medical) machine learning (MML) increases medical mixed realities' (MMR) clinical usability. Medical instruments have played a vital role in surgery for ages. To further accelerate the implementation of MML and MMR, three-dimensional (3D) datasets of instruments should be publicly available. The proposed data collection consists of 103, 3D-scanned medical instruments from the clinical routine, scanned with structured light scanners. The collection consists, for example, of instruments, like retractors, forceps, and clamps. The collection can be augmented by generating likewise models using 3D software, resulting in an inflated dataset for analysis. The collection can be used for general instrument detection and tracking in operating room settings, or a freeform marker-less instrument registration for tool tracking in augmented reality. Furthermore, for medical simulation or training scenarios in virtual reality and medical diminishing reality in mixed reality. We hope to ease research in the field of MMR and MML, but also to motivate the release of a wider variety of needed surgical instrument datasets.


Assuntos
Imageamento Tridimensional , Instrumentos Cirúrgicos , Realidade Virtual , Simulação por Computador , Software
5.
BMC Med Imaging ; 23(1): 174, 2023 10 31.
Artigo em Inglês | MEDLINE | ID: mdl-37907876

RESUMO

BACKGROUND: With the rise in importance of personalized medicine and deep learning, we combine the two to create personalized neural networks. The aim of the study is to show a proof of concept that data from just one patient can be used to train deep neural networks to detect tumor progression in longitudinal datasets. METHODS: Two datasets with 64 scans from 32 patients with glioblastoma multiforme (GBM) were evaluated in this study. The contrast-enhanced T1w sequences of brain magnetic resonance imaging (MRI) images were used. We trained a neural network for each patient using just two scans from different timepoints to map the difference between the images. The change in tumor volume can be calculated with this map. The neural networks were a form of a Wasserstein-GAN (generative adversarial network), an unsupervised learning architecture. The combination of data augmentation and the network architecture allowed us to skip the co-registration of the images. Furthermore, no additional training data, pre-training of the networks or any (manual) annotations are necessary. RESULTS: The model achieved an AUC-score of 0.87 for tumor change. We also introduced a modified RANO criteria, for which an accuracy of 66% can be achieved. CONCLUSIONS: We show a novel approach to deep learning in using data from just one patient to train deep neural networks to monitor tumor change. Using two different datasets to evaluate the results shows the potential to generalize the method.


Assuntos
Glioblastoma , Redes Neurais de Computação , Humanos , Imageamento por Ressonância Magnética , Encéfalo , Glioblastoma/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos
6.
JCO Clin Cancer Inform ; 7: e2300038, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37527475

RESUMO

PURPOSE: Quantifying treatment response to gastroesophageal junction (GEJ) adenocarcinomas is crucial to provide an optimal therapeutic strategy. Routinely taken tissue samples provide an opportunity to enhance existing positron emission tomography-computed tomography (PET/CT)-based therapy response evaluation. Our objective was to investigate if deep learning (DL) algorithms are capable of predicting the therapy response of patients with GEJ adenocarcinoma to neoadjuvant chemotherapy on the basis of histologic tissue samples. METHODS: This diagnostic study recruited 67 patients with I-III GEJ adenocarcinoma from the multicentric nonrandomized MEMORI trial including three German university hospitals TUM (University Hospital Rechts der Isar, Munich), LMU (Hospital of the Ludwig-Maximilians-University, Munich), and UME (University Hospital Essen, Essen). All patients underwent baseline PET/CT scans and esophageal biopsy before and 14-21 days after treatment initiation. Treatment response was defined as a ≥35% decrease in SUVmax from baseline. Several DL algorithms were developed to predict PET/CT-based responders and nonresponders to neoadjuvant chemotherapy using digitized histopathologic whole slide images (WSIs). RESULTS: The resulting models were trained on TUM (n = 25 pretherapy, n = 47 on-therapy) patients and evaluated on our internal validation cohort from LMU and UME (n = 17 pretherapy, n = 15 on-therapy). Compared with multiple architectures, the best pretherapy network achieves an area under the receiver operating characteristic curve (AUROC) of 0.81 (95% CI, 0.61 to 1.00), an area under the precision-recall curve (AUPRC) of 0.82 (95% CI, 0.61 to 1.00), a balanced accuracy of 0.78 (95% CI, 0.60 to 0.94), and a Matthews correlation coefficient (MCC) of 0.55 (95% CI, 0.18 to 0.88). The best on-therapy network achieves an AUROC of 0.84 (95% CI, 0.64 to 1.00), an AUPRC of 0.82 (95% CI, 0.56 to 1.00), a balanced accuracy of 0.80 (95% CI, 0.65 to 1.00), and a MCC of 0.71 (95% CI, 0.38 to 1.00). CONCLUSION: Our results show that DL algorithms can predict treatment response to neoadjuvant chemotherapy using WSI with high accuracy even before therapy initiation, suggesting the presence of predictive morphologic tissue biomarkers.


Assuntos
Adenocarcinoma , Aprendizado Profundo , Humanos , Terapia Neoadjuvante , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Adenocarcinoma/patologia , Junção Esofagogástrica/patologia
7.
8.
Eur Urol Open Sci ; 54: 28-32, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37361199

RESUMO

In this prospective two-center feasibility study, we evaluate the diagnostic value of intraoperative ex vivo specimenPET/CT imaging of radical prostatectomy (RP) and lymphadenectomy specimens. Ten patients with high-risk prostate cancer underwent clinical prostate-specific membrane antigen (PSMA) positron emission tomography/computed tomography (PET/CT) preoperatively on the day of surgery. Six patients received 68Ga-PSMA-11 and four 18F-PSMA-1007. Radioactivity of the resected specimen was measured again using a novel specimenPET/CT device (AURA10; XEOS Medical, Gent, Belgium) developed for intraoperative margin assessment. All index lesions of staging multiparametric magnetic resonance imaging could be visualized. Overall, specimenPET/CT correlated well with conventional PET/CT regarding detection of suspicious tracer foci (Pearson coefficient 0.935). In addition, specimenPET/CT demonstrated all lymph node metastases detected on conventional PET/CT (n = 3), as well as three previously undetected lymph node metastases. Importantly, all positive or close (<1 mm) surgical margins could be visualized in agreement with histopathology. In conclusion, specimenPET/CT enables detection of PSMA-avid lesions and warrants further investigation to tailor RP, based on a good correlation with final pathology. Future trials will prospectively compare ex vivo specimenPET/CT with a frozen section analysis for the detection of positive surgical margins and assessment of biochemical recurrence-free survival. Patient summary: In this report, we examined prostatectomy and lymphadenectomy specimens for suspicious positron emission tomography (PET) signals after preoperative tracer injection. It was found that in all cases, a good signal could be visualized, with a promising correlation of surface assessment compared with histopathology. We conclude that specimenPET imaging is feasible and may help improve oncological outcomes in the future.

9.
Comput Med Imaging Graph ; 107: 102238, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37207396

RESUMO

The segmentation of histopathological whole slide images into tumourous and non-tumourous types of tissue is a challenging task that requires the consideration of both local and global spatial contexts to classify tumourous regions precisely. The identification of subtypes of tumour tissue complicates the issue as the sharpness of separation decreases and the pathologist's reasoning is even more guided by spatial context. However, the identification of detailed tissue types is crucial for providing personalized cancer therapies. Due to the high resolution of whole slide images, existing semantic segmentation methods, restricted to isolated image sections, are incapable of processing context information beyond. To take a step towards better context comprehension, we propose a patch neighbour attention mechanism to query the neighbouring tissue context from a patch embedding memory bank and infuse context embeddings into bottleneck hidden feature maps. Our memory attention framework (MAF) mimics a pathologist's annotation procedure - zooming out and considering surrounding tissue context. The framework can be integrated into any encoder-decoder segmentation method. We evaluate the MAF on two public breast cancer and liver cancer data sets and an internal kidney cancer data set using famous segmentation models (U-Net, DeeplabV3) and demonstrate the superiority over other context-integrating algorithms - achieving a substantial improvement of up to 17% on Dice score. The code is publicly available at https://github.com/tio-ikim/valuing-vicinity.


Assuntos
Neoplasias Renais , Neoplasias Hepáticas , Humanos , Semântica , Algoritmos , Processamento de Imagem Assistida por Computador
10.
Invest Radiol ; 58(10): 754-765, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37222527

RESUMO

OBJECTIVES: In multiple myeloma and its precursor stages, plasma cell infiltration (PCI) and cytogenetic aberrations are important for staging, risk stratification, and response assessment. However, invasive bone marrow (BM) biopsies cannot be performed frequently and multifocally to assess the spatially heterogenous tumor tissue. Therefore, the goal of this study was to establish an automated framework to predict local BM biopsy results from magnetic resonance imaging (MRI). MATERIALS AND METHODS: This retrospective multicentric study used data from center 1 for algorithm training and internal testing, and data from center 2 to 8 for external testing. An nnU-Net was trained for automated segmentation of pelvic BM from T1-weighted whole-body MRI. Radiomics features were extracted from these segmentations, and random forest models were trained to predict PCI and the presence or absence of cytogenetic aberrations. Pearson correlation coefficient and the area under the receiver operating characteristic were used to evaluate the prediction performance for PCI and cytogenetic aberrations, respectively. RESULTS: A total of 672 MRIs from 512 patients (median age, 61 years; interquartile range, 53-67 years; 307 men) from 8 centers and 370 corresponding BM biopsies were included. The predicted PCI from the best model was significantly correlated ( P ≤ 0.01) to the actual PCI from biopsy in all internal and external test sets (internal test set: r = 0.71 [0.51, 0.83]; center 2, high-quality test set: r = 0.45 [0.12, 0.69]; center 2, other test set: r = 0.30 [0.07, 0.49]; multicenter test set: r = 0.57 [0.30, 0.76]). The areas under the receiver operating characteristic of the prediction models for the different cytogenetic aberrations ranged from 0.57 to 0.76 for the internal test set, but no model generalized well to all 3 external test sets. CONCLUSIONS: The automated image analysis framework established in this study allows for noninvasive prediction of a surrogate parameter for PCI, which is significantly correlated to the actual PCI from BM biopsy.


Assuntos
Aprendizado Profundo , Mieloma Múltiplo , Masculino , Humanos , Pessoa de Meia-Idade , Mieloma Múltiplo/diagnóstico por imagem , Mieloma Múltiplo/genética , Medula Óssea/diagnóstico por imagem , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Biópsia , Aberrações Cromossômicas
11.
Eur J Nucl Med Mol Imaging ; 50(7): 2196-2209, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36859618

RESUMO

PURPOSE: The aim of this study was to systematically evaluate the effect of thresholding algorithms used in computer vision for the quantification of prostate-specific membrane antigen positron emission tomography (PET) derived tumor volume (PSMA-TV) in patients with advanced prostate cancer. The results were validated with respect to the prognostication of overall survival in patients with advanced-stage prostate cancer. MATERIALS AND METHODS: A total of 78 patients who underwent [177Lu]Lu-PSMA-617 radionuclide therapy from January 2018 to December 2020 were retrospectively included in this study. [68Ga]Ga-PSMA-11 PET images, acquired prior to radionuclide therapy, were used for the analysis of thresholding algorithms. All PET images were first analyzed semi-automatically using a pre-evaluated, proprietary software solution as the baseline method. Subsequently, five histogram-based thresholding methods and two local adaptive thresholding methods that are well established in computer vision were applied to quantify molecular tumor volume. The resulting whole-body molecular tumor volumes were validated with respect to the prognostication of overall patient survival as well as their statistical correlation to the baseline methods and their performance on standardized phantom scans. RESULTS: The whole-body PSMA-TVs, quantified using different thresholding methods, demonstrate a high positive correlation with the baseline methods. We observed the highest correlation with generalized histogram thresholding (GHT) (Pearson r (r), p value (p): r = 0.977, p < 0.001) and Sauvola thresholding (r = 0.974, p < 0.001) and the lowest correlation with Multiotsu (r = 0.877, p < 0.001) and Yen thresholding methods (r = 0.878, p < 0.001). The median survival time of all patients was 9.87 months (95% CI [9.3 to 10.13]). Stratification by median whole-body PSMA-TV resulted in a median survival time from 11.8 to 13.5 months for the patient group with lower tumor burden and 6.5 to 6.6 months for the patient group with higher tumor burden. The patient group with lower tumor burden had significantly higher probability of survival (p < 0.00625) in eight out of nine thresholding methods (Fig. 2); those methods were SUVmax50 (p = 0.0038), SUV ≥3 (p = 0.0034), Multiotsu (p = 0.0015), Yen (p = 0.0015), Niblack (p = 0.001), Sauvola (p = 0.0001), Otsu (p = 0.0053), and Li thresholding (p = 0.0053). CONCLUSION: Thresholding methods commonly used in computer vision are promising tools for the semiautomatic quantification of whole-body PSMA-TV in [68Ga]Ga-PSMA-11-PET. The proposed algorithm-driven thresholding strategy is less arbitrary and less prone to biases than thresholding with predefined values, potentially improving the application of whole-body PSMA-TV as an imaging biomarker.


Assuntos
Neoplasias de Próstata Resistentes à Castração , Neoplasias da Próstata , Humanos , Masculino , Radioisótopos de Gálio , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons , Antígeno Prostático Específico , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/patologia , Neoplasias de Próstata Resistentes à Castração/patologia , Estudos Retrospectivos , Carga Tumoral
12.
Med Image Anal ; 85: 102757, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36706637

RESUMO

The HoloLens (Microsoft Corp., Redmond, WA), a head-worn, optically see-through augmented reality (AR) display, is the main player in the recent boost in medical AR research. In this systematic review, we provide a comprehensive overview of the usage of the first-generation HoloLens within the medical domain, from its release in March 2016, until the year of 2021. We identified 217 relevant publications through a systematic search of the PubMed, Scopus, IEEE Xplore and SpringerLink databases. We propose a new taxonomy including use case, technical methodology for registration and tracking, data sources, visualization as well as validation and evaluation, and analyze the retrieved publications accordingly. We find that the bulk of research focuses on supporting physicians during interventions, where the HoloLens is promising for procedures usually performed without image guidance. However, the consensus is that accuracy and reliability are still too low to replace conventional guidance systems. Medical students are the second most common target group, where AR-enhanced medical simulators emerge as a promising technology. While concerns about human-computer interactions, usability and perception are frequently mentioned, hardly any concepts to overcome these issues have been proposed. Instead, registration and tracking lie at the core of most reviewed publications, nevertheless only few of them propose innovative concepts in this direction. Finally, we find that the validation of HoloLens applications suffers from a lack of standardized and rigorous evaluation protocols. We hope that this review can advance medical AR research by identifying gaps in the current literature, to pave the way for novel, innovative directions and translation into the medical routine.


Assuntos
Realidade Aumentada , Humanos , Reprodutibilidade dos Testes
13.
J Cachexia Sarcopenia Muscle ; 14(1): 545-552, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36544260

RESUMO

BACKGROUND: Personalized therapy planning remains a significant challenge in advanced colorectal cancer care, despite extensive research on prognostic and predictive markers. A strong correlation of sarcopenia or overall body composition and survival has been described. Here, we explore whether automated assessment of body composition and liver metastases from standard of care CT images can add to clinical parameters in personalized survival risk prognostication. METHODS: We retrospectively analysed clinical imaging data from 85 patients (50.6% female, mean age 58.9 SD 12.2 years) with colorectal cancer and synchronous liver metastases. Pretrained deep learning models were used to assess body composition and liver metastasis geometry from abdominal CT images before the initiation of systemic treatment. Abdominal muscle-to-bone ratio (MBR) was calculated by dividing abdominal muscle volume by abdominal bone volume. MBR was compared with body mass index (BMI), abdominal muscle volume, and abdominal muscle volume divided by height squared. Differences in overall survival based on body composition and liver metastasis parameters were compared using Kaplan-Meier survival curves. Results were correlated with clinical and biomarker data to develop a machine learning model for survival risk prognostication. RESULTS: The MBR, unlike abdominal muscle volume or BMI, was significantly associated with overall survival (HR 0.39, 95% CI: 0.19-0.80, P = 0.009). The MBR (P = 0.022), liver metastasis surface area (P = 0.01) and primary tumour sidedness (P = 0.007) were independently associated with overall survival in multivariate analysis. Body composition parameters did not correlate with KRAS mutational status or primary tumour sidedness. A prediction model based on MBR, liver metastasis surface area and primary tumour sidedness achieved a concordance index of 0.69. CONCLUSIONS: Automated segmentation enables to extract prognostic parameters from routine imaging data for personalized survival modelling in advanced colorectal cancer patients.


Assuntos
Neoplasias Colorretais , Aprendizado Profundo , Neoplasias Hepáticas , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Estudos Retrospectivos , Carga Tumoral , Músculo Esquelético/patologia , Tomografia Computadorizada por Raios X , Neoplasias Colorretais/patologia , Composição Corporal
14.
Eur Radiol ; 33(2): 1031-1039, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35986768

RESUMO

OBJECTIVES: Low bone mineral density (BMD) was recently identified as a novel risk factor for patients with hepatocellular carcinoma (HCC). In this multicenter study, we aimed to validate the role of BMD as a prognostic factor for patients with HCC undergoing transarterial chemoembolization (TACE). METHODS: This retrospective multicenter trial included 908 treatment-naïve patients with HCC who were undergoing TACE as a first-line treatment, at six tertiary care centers, between 2010 and 2020. BMD was assessed by measuring the mean Hounsfield units (HUs) in the midvertebral core of the 11th thoracic vertebra, on contrast-enhanced computer tomography performed before treatment. We assessed the influence of BMD on median overall survival (OS) and performed multivariate analysis including established estimates for survival. RESULTS: The median BMD was 145 HU (IQR, 115-175 HU). Patients with a high BMD (≥ 114 HU) had a median OS of 22.2 months, while patients with a low BMD (< 114 HU) had a lower median OS of only 16.2 months (p < .001). Besides albumin, bilirubin, tumor number, and tumor diameter, BMD remained an independent prognostic factor in multivariate analysis. CONCLUSIONS: BMD is an independent predictive factor for survival in elderly patients with HCC undergoing TACE. The integration of BMD into novel scoring systems could potentially improve survival prediction and clinical decision-making. KEY POINTS: • Bone mineral density can be easily assessed in routinely acquired pre-interventional computed tomography scans. • Bone mineral density is an independent predictive factor for survival in elderly patients with HCC undergoing TACE. • Thus, bone mineral density is a novel imaging biomarker for prognosis prediction in elderly patients with HCC undergoing TACE.


Assuntos
Doenças Ósseas Metabólicas , Carcinoma Hepatocelular , Quimioembolização Terapêutica , Neoplasias Hepáticas , Humanos , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Prognóstico , Quimioembolização Terapêutica/métodos , Estudos Retrospectivos , Resultado do Tratamento
15.
Diagnostics (Basel) ; 12(11)2022 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-36359576

RESUMO

Head and neck cancer has great regional anatomical complexity, as it can develop in different structures, exhibiting diverse tumour manifestations and high intratumoural heterogeneity, which is highly related to resistance to treatment, progression, the appearance of metastases, and tumour recurrences. Radiomics has the potential to address these obstacles by extracting quantitative, measurable, and extractable features from the region of interest in medical images. Medical imaging is a common source of information in clinical practice, presenting a potential alternative to biopsy, as it allows the extraction of a large number of features that, although not visible to the naked eye, may be relevant for tumour characterisation. Taking advantage of machine learning techniques, the set of features extracted when associated with biological parameters can be used for diagnosis, prognosis, and predictive accuracy valuable for clinical decision-making. Therefore, the main goal of this contribution was to determine to what extent the features extracted from Computed Tomography (CT) are related to cancer prognosis, namely Locoregional Recurrences (LRs), the development of Distant Metastases (DMs), and Overall Survival (OS). Through the set of tumour characteristics, predictive models were developed using machine learning techniques. The tumour was described by radiomic features, extracted from images, and by the clinical data of the patient. The performance of the models demonstrated that the most successful algorithm was XGBoost, and the inclusion of the patients' clinical data was an asset for cancer prognosis. Under these conditions, models were created that can reliably predict the LR, DM, and OS status, with the area under the ROC curve (AUC) values equal to 0.74, 0.84, and 0.91, respectively. In summary, the promising results obtained show the potential of radiomics, once the considered cancer prognosis can, in fact, be expressed through CT scans.

16.
Radiol Artif Intell ; 4(5): e220055, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36204531

RESUMO

Purpose: To train a deep natural language processing (NLP) model, using data mined structured oncology reports (SOR), for rapid tumor response category (TRC) classification from free-text oncology reports (FTOR) and to compare its performance with human readers and conventional NLP algorithms. Materials and Methods: In this retrospective study, databases of three independent radiology departments were queried for SOR and FTOR dated from March 2018 to August 2021. An automated data mining and curation pipeline was developed to extract Response Evaluation Criteria in Solid Tumors-related TRCs for SOR for ground truth definition. The deep NLP bidirectional encoder representations from transformers (BERT) model and three feature-rich algorithms were trained on SOR to predict TRCs in FTOR. Models' F1 scores were compared against scores of radiologists, medical students, and radiology technologist students. Lexical and semantic analyses were conducted to investigate human and model performance on FTOR. Results: Oncologic findings and TRCs were accurately mined from 9653 of 12 833 (75.2%) queried SOR, yielding oncology reports from 10 455 patients (mean age, 60 years ± 14 [SD]; 5303 women) who met inclusion criteria. On 802 FTOR in the test set, BERT achieved better TRC classification results (F1, 0.70; 95% CI: 0.68, 0.73) than the best-performing reference linear support vector classifier (F1, 0.63; 95% CI: 0.61, 0.66) and technologist students (F1, 0.65; 95% CI: 0.63, 0.67), had similar performance to medical students (F1, 0.73; 95% CI: 0.72, 0.75), but was inferior to radiologists (F1, 0.79; 95% CI: 0.78, 0.81). Lexical complexity and semantic ambiguities in FTOR influenced human and model performance, revealing maximum F1 score drops of -0.17 and -0.19, respectively. Conclusion: The developed deep NLP model reached the performance level of medical students but not radiologists in curating oncologic outcomes from radiology FTOR.Keywords: Neural Networks, Computer Applications-Detection/Diagnosis, Oncology, Research Design, Staging, Tumor Response, Comparative Studies, Decision Analysis, Experimental Investigations, Observer Performance, Outcomes Analysis Supplemental material is available for this article. © RSNA, 2022.

17.
Sci Rep ; 12(1): 13419, 2022 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-35927564

RESUMO

Patients with neuroendocrine tumors of gastro-entero-pancreatic origin (GEP-NET) experience changes in fat and muscle composition. Dual-energy X-ray absorptiometry (DXA) and bioelectrical impedance analysis (BIA) are currently used to analyze body composition. Changes thereof could indicate cancer progression or response to treatment. This study examines the correlation between CT-based (computed tomography) body composition analysis (BCA) and DXA or BIA measurement. 74 GEP-NET-patients received whole-body [68Ga]-DOTATOC-PET/CT, BIA, and DXA-scans. BCA was performed based on the non-contrast-enhanced, 5 mm, whole-body-CT images. BCA from CT shows a strong correlation between body fat ratio with DXA (r = 0.95, ρC = 0.83) and BIA (r = 0.92, ρC = 0.76) and between skeletal muscle ratio with BIA: r = 0.81, ρC = 0.49. The deep learning-network achieves highly accurate results (mean Sørensen-Dice-score 0.93). Using BCA on routine Positron emission tomography/CT-scans to monitor patients' body composition in the diagnostic workflow can reduce additional exams whilst substantially amplifying measurement in slower progressing cancers such as GEP-NET.


Assuntos
Composição Corporal , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Absorciometria de Fóton/métodos , Composição Corporal/fisiologia , Índice de Massa Corporal , Impedância Elétrica , Humanos , Tomografia Computadorizada por Raios X
18.
Eur J Nucl Med Mol Imaging ; 49(13): 4503-4515, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35904589

RESUMO

PURPOSE: Both digital positron emission tomography (PET) detector technologies and artificial intelligence based image post-reconstruction methods allow to reduce the PET acquisition time while maintaining diagnostic quality. The aim of this study was to acquire ultra-low-count fluorodeoxyglucose (FDG) ExtremePET images on a digital PET/computed tomography (CT) scanner at an acquisition time comparable to a CT scan and to generate synthetic full-dose PET images using an artificial neural network. METHODS: This is a prospective, single-arm, single-center phase I/II imaging study. A total of 587 patients were included. For each patient, a standard and an ultra-low-count FDG PET/CT scan (whole-body acquisition time about 30 s) were acquired. A modified pix2pixHD deep-learning network was trained employing 387 data sets as training and 200 as test cohort. Three models (PET-only and PET/CT with or without group convolution) were compared. Detectability and quantification were evaluated. RESULTS: The PET/CT input model with group convolution performed best regarding lesion signal recovery and was selected for detailed evaluation. Synthetic PET images were of high visual image quality; mean absolute lesion SUVmax (maximum standardized uptake value) difference was 1.5. Patient-based sensitivity and specificity for lesion detection were 79% and 100%, respectively. Not-detected lesions were of lower tracer uptake and lesion volume. In a matched-pair comparison, patient-based (lesion-based) detection rate was 89% (78%) for PERCIST (PET response criteria in solid tumors)-measurable and 36% (22%) for non PERCIST-measurable lesions. CONCLUSION: Lesion detectability and lesion quantification were promising in the context of extremely fast acquisition times. Possible application scenarios might include re-staging of late-stage cancer patients, in whom assessment of total tumor burden can be of higher relevance than detailed evaluation of small and low-uptake lesions.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Inteligência Artificial , Estudos Prospectivos , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos
19.
Eur Radiol ; 32(12): 8769-8776, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35788757

RESUMO

OBJECTIVES: Over the course of their treatment, patients often switch hospitals, requiring staff at the new hospital to import external imaging studies to their local database. In this study, the authors present MOdality Mapping and Orchestration (MOMO), a Deep Learning-based approach to automate this mapping process by combining metadata analysis and a neural network ensemble. METHODS: A set of 11,934 imaging series with existing anatomical labels was retrieved from the PACS database of the local hospital to train an ensemble of neural networks (DenseNet-161 and ResNet-152), which process radiological images and predict the type of study they belong to. We developed an algorithm that automatically extracts relevant metadata from imaging studies, regardless of their structure, and combines it with the neural network ensemble, forming a powerful classifier. A set of 843 anonymized external studies from 321 hospitals was hand-labeled to assess performance. We tested several variations of this algorithm. RESULTS: MOMO achieves 92.71% accuracy and 2.63% minor errors (at 99.29% predictive power) on the external study classification task, outperforming both a commercial product (82.86% accuracy, 1.36% minor errors, 96.20% predictive power) and a pure neural network ensemble (72.69% accuracy, 10.3% minor errors, 99.05% predictive power) performing the same task. We find that the highest performance is achieved by an algorithm that combines all information into one vote-based classifier. CONCLUSION: Deep Learning combined with metadata matching is a promising and flexible approach for the automated classification of external DICOM studies for PACS archiving. KEY POINTS: • The algorithm can successfully identify 76 medical study types across seven modalities (CT, X-ray angiography, radiographs, MRI, PET (+CT/MRI), ultrasound, and mammograms). • The algorithm outperforms a commercial product performing the same task by a significant margin (> 9% accuracy gain). • The performance of the algorithm increases through the application of Deep Learning techniques.


Assuntos
Aprendizado Profundo , Humanos , Redes Neurais de Computação , Algoritmos , Bases de Dados Factuais , Imageamento por Ressonância Magnética/métodos
20.
Eur Radiol ; 32(12): 8617-8628, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35678860

RESUMO

OBJECTIVES: In the Cancer Core Europe Consortium (CCE), standardized biomarkers are required for therapy monitoring oncologic multicenter clinical trials. Multiparametric functional MRI and particularly diffusion-weighted MRI offer evident advantages for noninvasive characterization of tumor viability compared to CT and RECIST. A quantification of the inter- and intraindividual variation occurring in this setting using different hardware is missing. In this study, the MRI protocol including DWI was standardized and the residual variability of measurement parameters quantified. METHODS: Phantom and volunteer measurements (single-shot T2w and DW-EPI) were performed at the seven CCE sites using the MR hardware produced by three different vendors. Repeated measurements were performed at the sites and across the sites including a traveling volunteer, comparing qualitative and quantitative ROI-based results including an explorative radiomics analysis. RESULTS: For DWI/ADC phantom measurements using a central post-processing algorithm, the maximum deviation could be decreased to 2%. However, there is no significant difference compared to a decentralized ADC value calculation at the respective MRI devices. In volunteers, the measurement variation in 2 repeated scans did not exceed 11% for ADC and is below 20% for single-shot T2w in systematic liver ROIs. The measurement variation between sites amounted to 20% for ADC and < 25% for single-shot T2w. Explorative radiomics classification experiments yield better results for ADC than for single-shot T2w. CONCLUSION: Harmonization of MR acquisition and post-processing parameters results in acceptable standard deviations for MR/DW imaging. MRI could be the tool in oncologic multicenter trials to overcome the limitations of RECIST-based response evaluation. KEY POINTS: • Harmonizing acquisition parameters and post-processing homogenization, standardized protocols result in acceptable standard deviations for multicenter MR-DWI studies. • Total measurement variation does not to exceed 11% for ADC in repeated measurements in repeated MR acquisitions, and below 20% for an identical volunteer travelling between sites. • Radiomic classification experiments were able to identify stable features allowing for reliable discrimination of different physiological tissue samples, even when using heterogeneous imaging data.


Assuntos
Imagem de Difusão por Ressonância Magnética , Neoplasias , Humanos , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Neoplasias/diagnóstico por imagem , Europa (Continente) , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA